<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15082</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: timeout moving roller cylinder
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The roller did not reach its destination in the "aldly roller" time allowed.
Check for faulty roller sensors by using the "rlr" command from the diagnostic.  If the sensor is
faulty, use "set al nrs 1" or "set al rs 0" to bypass the sensor and get the customer going.
Arrange for field service.  If the sensor is OK, test the roller actuator by using "rlr on" or
"rlr off" and see if any motion occurs.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Select Resume if that option is available.  Call the Creo Response Centre if the problem persists.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty roller cylinder.  Try moving it manually with "rlr on" and "rlr off" commands.
</Cause>
<Cause>
Failed/loose roller sensors.
</Cause>
<Cause>
For 3244 Platsetter: This error is reported if the drum roller sensors do not sense
the roller in the lowered position within "aldly roller" seconds,
if sensors enabled. (during load4)
</Cause>
<Cause>
For 3244 Platesetter: This error is reported if the drum roller sensors do not sense
the roller in the raised position within "aldly roller" seconds,
if sensors enabled. (during load6 &amp; unload5)
</Cause>
<Cause>
For 3244 Platesetter: If after a timeout of "aldly roller" seconds the roller sensors
indicate both up and down at the same time or (up and not down) then
this error is reported. note if the sensors indicate neither up nor down
(ie probably half way) then E_ALE_DRLR_TIMEOUT2 is reported.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/aldly_cal_roller.xml</LinkAddress><LinkTitle>NVS: aldly roller</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_nrs.xml</LinkAddress><LinkTitle>NVS: al nrs</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_rs.xml</LinkAddress><LinkTitle>NVS: al rs</LinkTitle></Link>
<Link><LinkAddress>../commands/rlr.xml</LinkAddress><LinkTitle>Command: rlr</LinkTitle></Link>
<Link><LinkAddress>../error_messages/15066.xml</LinkAddress><LinkTitle>E_ALE_DRLR_TIMEOUT2</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:51 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/trendsetter_3244/content/troubleshooting/15082.htm</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>